TEOS 100 XL RT

1 - 10 kVA

Long Time Backup Option, True Double-Conversion, Microprocessor Control

Mostrar Más

Áreas de Uso

Características Generales

TEOS 100 XL RT

TEOS 100 XL RT

1 - 10 kVA

1 Phase In / 1 Phase Out

  • Rackmount design for Rack Cabinet applications
  • True double-conversion
  • Microprocessor control optimizes reliability
  • Input power factor correction
  • Wide input voltage
  • Converter mode available
  • ECO mode for energy saving (Only available for 1-3kVA models)
  • Generator compatible
  • Manuel bypass is available for 6-10kVA
  • Adjustable battery numbers only available for 6/10kVA models
  • Adjustable charging current via LCD or soſtware (1A~ 6A)
  • Emergency power off (EPO) function is only available for 6/10kVA models
  • Comprehensive display allows easy monitoring and access to UPS status
TECHNICIAL SPECIFICATIONS
PhaseSingle phase with ground
Capacity1000VA / 800W
INPUT
Nominal Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Input voltage range60-150 VAC or 120-300 VAC (Based on load at 50%)
90-140 VAC or 180-280 VAC (Based on load at 100%)
Frequency range40Hz ~ 70 Hz
Power factor≥ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Power factor0,8
Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage regulation± 1%
Frequency range47~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency range50 Hz or 60Hz ± 0.5% (Batt. Mode)
Output current crest factor3:1 (max.)
ITHD≤ 3% THD (linear load)
≤ 6% THD (non-linear load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypass4 ms
Waveform (batt. mode)Pure Sinewave
EFFICIENCY
AC Mode88%
Battery Mode83%
BATTERY
Battery typeDepending on the applications
Numbers2
Typical recharge time4 hour recover to 90% capacity
Charging current1A/2A/4A/6A (adjustable)
Float charging voltage27.4VDC ± 1%
41.9VDC ± 1%
INDICATORS
LCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
RT Model | Dimension (mm) HxWxD88(2U)x438x310
RT Model | Weight (kg)9
ENVIRONMENT
Humidity20-90% RH @ 0- 40°C (non-condensing)
Acoustic Noise< 50dBA @ 1 meter
Managament
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
TECHNICIAL SPECIFICATIONS
PhaseSingle phase with ground
Capacity2000VA / 1600W
INPUT
Nominal Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Input voltage range60-150 VAC or 120-300 VAC (Based on load at 50%)
90-140 VAC or 180-280 VAC (Based on load at 100%)
Frequency range40Hz ~ 70 Hz
Power factor≥ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Power factor0,8
Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage regulation± 1%
Frequency range47~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency range50 Hz or 60Hz ± 0.5% (Batt. Mode)
Output current crest factor3:1 (max.)
ITHD≤ 3% THD (linear load)
≤ 6% THD (non-linear load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypass4 ms
Waveform (batt. mode)Pure Sinewave
EFFICIENCY
AC Mode89%
Battery Mode85%
BATTERY
Battery typeDepending on the applications
Numbers4
Typical recharge time4 hour recover to 90% capacity
Charging current1A/2A/4A/6A (adjustable)
Float charging voltage54.7 VDC ± 1%
82.1VDC ± 1%
109.4 VDC ± 1%
INDICATORS
LCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
RT Model | Dimension (mm) HxWxD88(2U)x438x410
RT Model | Weight (kg)12
ENVIRONMENT
Humidity20-90% RH @ 0- 40°C (non-condensing)
Acoustic Noise< 50dBA @ 1 meter
Managament
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
TECHNICIAL SPECIFICATIONS
PhaseSingle phase with ground
Capacity3000VA / 2400W
INPUT
Nominal Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Input voltage range60-150 VAC or 120-300 VAC (Based on load at 50%)
90-140 VAC or 180-280 VAC (Based on load at 100%)
Frequency range40Hz ~ 70 Hz
Power factor≥ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Power factor0,8
Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage regulation± 1%
Frequency range47~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency range50 Hz or 60Hz ± 0.5% (Batt. Mode)
Output current crest factor3:1 (max.)
ITHD≤ 3% THD (linear load)
≤ 6% THD (non-linear load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypass4 ms
Waveform (batt. mode)Pure Sinewave
EFFICIENCY
AC Mode90%
Battery Mode88%
BATTERY
Battery typeDepending on the applications
Numbers6
Typical recharge time4 hour recover to 90% capacity
Charging current1A/2A/4A/6A (adjustable)
Float charging voltage82.1 VDC ± 1%
109.4 VDC ± 1%
INDICATORS
LCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
RT Model | Dimension (mm) HxWxD88(2U)x438x410
RT Model | Weight (kg)14.2
ENVIRONMENT
Humidity20-90% RH @ 0- 40°C (non-condensing)
Acoustic Noise< 50dBA @ 1 meter
Managament
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
TECHNICIAL SPECIFICATIONS
PhaseSingle phase with ground
Capacity6000VA / 5400W
INPUT
Nominal Voltage208/220/230/240VAC
Input voltage range110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)
Frequency range46~54 Hz or 56~64 Hz
Power factor≥ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Power factor0,9
Voltage208/220/230/240VAC
Voltage regulation± 1%
Frequency range46~54 Hz or 56~64 Hz (Synchronized Range)
Frequency range50 Hz or 60Hz ± 0.1 Hz (Batt. Mode)
Output current crest factor3:1 (max.)
ITHD≤ 3% THD (linear load)
≤ 5% THD (non-linear load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypassZero
Waveform (batt. mode)Pure Sinewave
EFFICIENCY
AC Mode92%
Battery Mode90%
BATTERY
Battery typeDepending on the applications
Numbers16-20 (adjustable)
Typical recharge time9 hour recover to 90% capacity
Charging current1A/2A/4A/6A (adjustable, only for 6A 16 pcs batt. configuration)
Float charging voltage273 VDC ± 1% (according to 20 batt.-powered configuration)
INDICATORS
LCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
RT Model | Dimension (mm) HxWxD88(2U)x438x530
RT Model | Weight (kg)15
ENVIRONMENT
Humidity0-95% RH @ 0-40°C (non-condensing)
Acoustic Noise< 55dBA @ 1 meter
Managament
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
TECHNICIAL SPECIFICATIONS
PhaseSingle phase with ground
Capacity10000VA / 9000W
INPUT
Nominal Voltage208/220/230/240VAC
Input voltage range110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)
Frequency range46~54 Hz or 56~64 Hz
Power factor≥ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Power factor0,9
Voltage208/220/230/240VAC
Voltage regulation± 1%
Frequency range46~54 Hz or 56~64 Hz (Synchronized Range)
Frequency range50 Hz or 60Hz ± 0.1 Hz (Batt. Mode)
Output current crest factor3:1 (max.)
ITHD≤ 3% THD (linear load)
≤ 5% THD (non-linear load)
Transfer time | AC Mode -> Battery ModeZero
Transfer time | Inverter -> bypassZero
Waveform (batt. mode)Pure Sinewave
EFFICIENCY
AC Mode93%
Battery Mode91%
BATTERY
Battery typeDepending on the applications
Numbers16-20 (adjustable)
Typical recharge time9 hour recover to 90% capacity
Charging current1A/2A/4A/6A (adjustable, only for 6A 16 pcs batt. configuration)
Float charging voltage273 VDC ± 1% (according to 20 batt.-powered configuration)
INDICATORS
LCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
RT Model | Dimension (mm) HxWxD133(3U)x438x580
RT Model | Weight (kg)18
ENVIRONMENT
Humidity0-95% RH @ 0-40°C (non-condensing)
Acoustic Noise< 58dBA @ 1 meter
Managament
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser

NombreTamaño del Archivo
1)TEOS 100 XL RT SERIES (1 - 10 kVA)-