DS POWER

500 - 600 kW

The new DS Power range UPS uses the latest DSP technology to be programmed to suit a wide variety of electrical environments without impending its performance. With the DS Power range, efficiency, reliability and functionality are enhanced to levels...

Показать больше

Области использования

Общие особенности

DS POWER

IGBT RECTIFIER

DSP CONTROL

The new DS Power range UPS uses the latest DSP technology to be programmed to suit a wide variety of electrical environments without impending its performance. With the DS Power range, efficiency, reliability and functionality are enhanced to levels unattainable with the old analogue technology. This technology does not only create significant increase in MTBF, but the capability of DSP to accurately manipulate signals at very high speed permits all the UPS subsystems to be controlled with greatly increased precision

  • Transformerless UPS topology
  • Low input current total harmonic distortion (THD)
  • High input power factor
  • High efficiency up to 94.5%
  • Cold start function
  • Static and maintenance by-pass switch
  • Output short circuit and overload protection
  • External REPO switch input
  • 512 events memory (512 events 45000 alarms)
  • Clock and calender (battery supported)
  • Automatic battery test, remaining battery time indicator
  • Temperature compansated charge system (optional)
  • 2 RS232 serial ports and 12 dry contact outputs
  • 3 DSP controlled modular structure
  • Optional SNMP and MODBUS adaptors
  • Optional graphical panel
  • Optional usb flash memory
  • Full digital structure
  • Small footprint
  • Ecomode operation (optional)
  • Fewer electronic components
  • Output current limiting
  • Advanced diagnostics for the input
  • Selectable input/output coltage/frequency/range
  • Split by-pass input (second input)
  • Output DC leakage protection
  • Separate DSP for inverter control
  • Separate DSP for the PFC
  • 3 level battery protection
  • High charge current capacity
  • Charge/discharge current indicator
  • Advanced remote control features
  • Manufactured according to EC Directive; EN62040
  • 2 years warranty
TECHNICIAL SPECIFICATIONS
Güç (kVA=kW)500
INPUT
Voltage380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency50Hz / 60Hz , ± %5
Power factor (at100% load)≥ 0.99
THDI (*)≤ %3
By-Pass Voltage380/400 VAC 3 Phase + N, ± 10%
ProtectionFuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW)500
Power factor1
Voltage380/400 VAC 3 Phase + N , ± 1% (415 optional)
Frequency50Hz / 60Hz
Frequency ToleranceLine synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency (at 100% load)up to 95%
Output current crest factor3:1
Overload Protection100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other ProtectionsAdvanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
THD≤ 2% (at 100% linear load)
BATTERIES
TypeVRLA AGM / GEL / NiCd
Battery Number± 360 VDC (2x30 batteries)
Float charging voltage2x405 VDC
Float / End of dischg voltage± 405 VDC / ± 300 VDC
Battery HousingExternal
Battery ambient temp25ºC
Protections3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic TestingStandard every 72 hours (adjustable)
GENEL
StandardsEN62040-1, EN62040-2, EN62040-3
User Interface5 vector buttons, Buzzer, TFT panel
IndicatorsP-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
AdvancedSelf diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
InputsEPO input, Interactive battery panel input, Genset input
Genset KitStandard (programmable)
SoſtwareStandard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm LoggingStandard:with time & date 512 events
ProtectionsPower module over-temperature, Overcurrent, Temperature high alarm
Temperature Range0ºC - 40ºC
Protection classIP20
Relative humidity90% max. (non-condensing)
Altitude< 1000m above sea level
Noise level< 72 dBA
Weight (kg)1452
Dimension (mm) HxWxD1610x1050x1940
OPTIONS
Input / Output voltagePlease ask
TransformerGalvanic isolation transformer at the input & output (internal)
SoſtwareT-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 10-50-100-200 clients
Comm. adaptorsSNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parralel OperationUp to 8 units
Power factorOpsiyonel olarak 0.8 yapılır. Ancak boyutlarda değişiklik gösterebilir.
(*)Depending on power and input/output conditions
TECHNICIAL SPECIFICATIONS
Güç (kVA=kW)600
INPUT
Voltage380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency50Hz / 60Hz , ± %5
Power factor (at100% load)≥ 0.99
THDI (*)≤ %3
By-Pass Voltage380/400 VAC 3 Phase + N, ± 10%
ProtectionFuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW)600
Power factor1
Voltage380/400 VAC 3 Phase + N , ± 1% (415 optional)
Frequency50Hz / 60Hz
Frequency ToleranceLine synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency (at 100% load)up to 95%
Output current crest factor3:1
Overload Protection100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other ProtectionsAdvanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
THD≤ 2% (at 100% linear load)
BATTERIES
TypeVRLA AGM / GEL / NiCd
Battery Number± 360 VDC (2x30 batteries)
Float charging voltage2x405 VDC
Float / End of dischg voltage± 405 VDC / ± 300 VDC
Battery HousingExternal
Battery ambient temp25ºC
Protections3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic TestingStandard every 72 hours (adjustable)
GENEL
StandardsEN62040-1, EN62040-2, EN62040-3
User Interface5 vector buttons, Buzzer, TFT panel
IndicatorsP-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
AdvancedSelf diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
InputsEPO input, Interactive battery panel input, Genset input
Genset KitStandard (programmable)
SoſtwareStandard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm LoggingStandard:with time & date 512 events
ProtectionsPower module over-temperature, Overcurrent, Temperature high alarm
Temperature Range0ºC - 40ºC
Protection classIP20
Relative humidity90% max. (non-condensing)
Altitude< 1000m above sea level
Noise level< 72 dBA
Weight (kg)1452
Dimension (mm) HxWxD1610x1050x1940
OPTIONS
Input / Output voltagePlease ask
TransformerGalvanic isolation transformer at the input & output (internal)
SoſtwareT-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 10-50-100-200 clients
Comm. adaptorsSNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parralel OperationUp to 8 units
Power factorOpsiyonel olarak 0.8 yapılır. Ancak boyutlarda değişiklik gösterebilir.
(*)Depending on power and input/output conditions

ИмяРазмер файла
1)DS POWER SERIES (400 - 600 kW)-