TVR 11

5 - 50 kVA

Full automatic voltage regulator, Non-linear charges drive, 1 phase input 1 phase output, Wide power and voltage interval, High reliability thanks to Microprocessor and Smart Driver, Fast Regulation, High efficiency...

Mostrar Más

Áreas de Uso

Características Generales

TVR 11

TVR 11

5 - 50 kVA

FULL AUTOMATIC VOLTAGE REGULATOR

  • Non-linear charges drive
  • 1 phase input 1 phase output
  • Wide power and voltage interval
  • High reliability thanks to Microprocessor and Smart Driver
  • Fast Regulation
  • High efficiency
  • Load transfer to Bypass via pole charge switch
  • Safe and economic usage
  • Low and overvoltage protections
  • Overload protection(optional)
  • Digitally displayed status, input & output measurements
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)5
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output18
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)55x37x30
Weight (kg)30
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)7,5
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output27
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)55x37x30
Weight (kg)34
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)10
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output36
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)55x37x30
Weight (kg)47
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)15
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output54
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)34x59x42
Weight (kg)55
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)20
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output72
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)85x50x52
Weight (kg)95
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)25
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output90
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)85x50x52
Weight (kg)110
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)30
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output108
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)85x50x52
Weight (kg)130
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)40
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output144
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)85x50x62
Weight (kg)155
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)50
INPUT
Input Voltage Correction Invertal165 - 255 / 110 - 240 VAC (Optional)
Input Voltage Operating Interval90 - 285 VAC
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
OUTPUT
Output voltage220/230/240 VAC RMS ± %1
Overload10 Sn. %200 yük
Correction Speed~ 90 Volt / Sn.
Upturn Period~ 90 Volt / Sn. (160 VAC - 260 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs
Current at output180
GENEL
Working PrincipleServo Motor, Mikroişlemci Kontrollü, Tam Otomatik
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 96 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Off
Protection classIP 20 // IP 54 (Optional)
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / 60 °C
Relative humidity< 90 %, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 50 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)85x50x62
Weight (kg)180