TVR 33 H

200 - 3000 kVA

Full automatic voltage regulator, Non-linear charges drive, 3 phase input 3 phase output, Wide power and voltage interval, High reliability thanks to Microprocessor and Smart Driver, Fast Regulation

Show More

Areas of Usage

General Features

TVR 33 H

TVR 33 H

200 - 3000 kVA

FULL AUTOMATIC VOLTAGE REGULATOR

  • Non-linear charges drive
  • 3 phase input 3 phase output
  • Wide power and voltage interval
  • High reliability thanks to Microprocessor and Smart Driver
  • Fast Regulation
  • High efficiency
  • Load transfer to Bypass via pole charge switch
  • Safe and economic usage
  • Overcurrent and overload protection
  • Digitally displayed status, input & output measurements
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)200
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output323
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output243
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)200x120x80
Weight (kg)1050
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)250
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output404
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output303
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)200x120x80
Weight (kg)1100
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)300
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output484
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output363
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)200x120x80
Weight (kg)1200
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)400
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output646
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output484
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)200x175x80
Weight (kg)1650
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)500
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output808
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output606
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)175x180x122
Weight (kg)2000
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)600
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output968
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output729
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)175x180x122
Weight (kg)2100
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)800
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output1292
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output972
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)208x210x144
Weight (kg)2900
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)1000
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output1616
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output1215
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)185x210x214
Weight (kg)3450
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)1250
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output2020
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output1515
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)208x240x214
Weight (kg)3900
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)1500
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output2424
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output1818
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)188x240x264
Weight (kg)4300
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)2000
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output3232
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output2430
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)208x240x264
Weight (kg)6000
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)2500
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output4040
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output3030
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)Special
Weight (kg)Special
TECHNICIAL SPECIFICATIONS
Nominal power (kVA)3000
INPUT
Input Voltage Correction Invertal285 - 440 VAC (Optional: 190-415 VAC)
Input Voltage Operating Interval
Operation Frequency47...65 Hz
Line Input ProtectionOvercurrent, Low and High voltage protection
Current at output4848
OUTPUT
Output Voltage380 / 400 / 415 VAC RMS ± 1 %
Overload10 Sec. 200 % Load
Correction Speed~ 90 Volt / Sec.
Upturn Period~ 90 Volt / Sec. ( 160 VAC - 250 VAC)
Output ProtectionProtects load by opening the circuit when overburden, short circuit occurs.
Current at output3645
GENEL
Working PrincipleServo Motor, Microprocessor Controlled, Full Automatic
CoolingAkıllı fan sistemi
Measured Value MonitorTESCOM TRUE RMS Panel Voltmeter (74x74mm) output voltage and line voltage monitorization
Total Efficiency> 97 %
Mechanical by-passManually Controlled Line - PAKO Switch Selects Voltage Regulator Switch Turn On / Of
Protection classIP 20
ENVIRONMENTAL DATA
Operating temperature-10 °C / 50 °C
Storage temperature-25 °C / + 60 °C
Relative humidity< %90, DIN ( 40040 )
Altitude< 2000 m.
Noise level< 55 dB
StandardsCE / ISO 9001
Dimensions
HxWxD (cm)Special
Weight (kg)Special